Faber Cylinders for Scuba Diving

Water Capacity > 1 5.5 litre

 See Notes


Water
Capacity
(litre)
Diameter
(mm)
Filling
Pressure
(bar)
Empty
Weight
(kg)
Standard
Climatic
Area
(BS only)
Comments
  1.2
  90
  184
  1.7
  DOT 3AA / TC3AAM
 
  DOT 3AA: W.P.2640 PSI (INCLUDING 10% OVERFILLING)
  1.5
  100
  200
  2.4
  EN 1964-1:1999 (PED)
 
  Approved PED 97/23/EC
  1.5
  100
  232
  2.4
  EN 1964-1:1999 (PED)
 
  Approved PED 97/23/EC
  2
  100
  182
  3
  DOT EXEMPTION
 
 
  2
  100
  182
  3
  DOT / TC EXEMPTION
 
 
  2
  100
  184
  2.7
  DOT 3AA / TC3AAM
 
  DOT 3AA: W.P.2640 PSI (INCLUDING 10% OVERFILLING)
  2
  100
  200
  2.5
  CEE/EEC/EWG 84/525 (EUROPE)
 
  2
  100
  200
  2.6
  EN 1964-1:1999 (PED) FOR RINA
 
  Approved PED 97/23/EC
  2
  100
  200
  2.6
  EN 1964-1:1999 (PED)
 
  Approved PED 97/23/EC
  2
  100
  200
  2.9
  EN 1964-1:1999
 
  2
  100
  232
  2.6
  BS 5045-7:2000(PED)
  UK
  Approved PED 97/23/EC
  2
  100
  232
  2.6
  BS 5045-7:2000
  UK
  2
  100
  232
  2.6
  BS5045 P.1+ LATEST AMENDMENTS
  UK
 
  2
  100
  232
  2.8
  EN 1964-1:1999 (PED)
 
  Approved PED 97/23/EC
  2
  100
  237
  3
  DOT / TC EXEMPTION
 
 
  2
  100
  237
  3
  DOT EXEMPTION
 
 
  2
  100
  300
  3.6
  EUROPEAN REGULATIONS
 
  2
  100
  300
  3.6
  EN 1964-1:1999
 
  2
  100
  300
  3.6
  CEE/EEC/EWG 84/525 (EUROPE)
 
  2
  100
  300
  3.6
  EN 1964-1:1999 (PED)
 
  Approved PED 97/23/EC
  2.5
  100
  200
  2.9
  CEE/EEC/EWG 84/525 (EUROPE)
 
  2.5
  100
  200
  3.1
  EN 1964-1:1999 (PED) FOR RINA
 
  Approved PED 97/23/EC
  2.5
  100
  200
  3.1
  EN 1964-1:1999 (PED)
 
  Approved PED 97/23/EC
  2.5
  100
  200
  3.5
  EN 1964-1:1999
 
  2.5
  100
  232
  3.3
  EN 1964-1:1999 (PED)
 
  Approved PED 97/23/EC
  2.5
  100
  232
  3
  BS5045 P.1+ LATEST AMENDMENTS
  UK
 
  2.5
  100
  232
  3
  BS 5045-7:2000(PED)
  UK
  Approved PED 97/23/EC
  2.5
  100
  232
  3
  BS 5045-7:2000
  UK
  2.5
  100
  300
  4.3
  EUROPEAN REGULATIONS
 
  2.5
  100
  300
  4.3
  CEE/EEC/EWG 84/525 (EUROPE)
 
  2.5
  115
  200
  3.2
  CEE/EEC/EWG 84/525 FOR RINA
 
  2.5
  115
  200
  3.2
  CEE/EEC/EWG 84/525 (EUROPE)
 
  2.5
  115
  200
  3.3
  EN 1964-1:1999 (PED) FOR RINA
 
  Approved PED 97/23/EC
  2.5
  115
  200
  3.3
  EN 1964-1:1999 (PED)
 
  Approved PED 97/23/EC
  2.5
  115
  300
  3.6
  EUROPEAN REGULATIONS
 
  2.9
  115
  200
  3.6
  CEE/EEC/EWG 84/525 FOR RINA
 
  3
  100
  182
  3.9
  DOT / TC EXEMPTION
 
 
  3
  100
  182
  3.9
  DOT EXEMPTION
 
 
  3
  100
  184
  3.7
  DOT 3AA / TC3AAM
 
  DOT 3AA: W.P.2640 PSI (INCLUDING 10% OVERFILLING)
  3
  100
  200
  3.5
  CEE/EEC/EWG 84/525 (EUROPE)
 
  3
  100
  200
  3.6
  EN 1964-1:1999 (PED) FOR RINA
 
  Approved PED 97/23/EC
  3
  100
  200
  3.6
  EN 1964-1:1999 (PED)
 
  Approved PED 97/23/EC
  3
  100
  200
  3.9
  EN 1964-1:1999
 
  3
  100
  230
  4.6
  DOT 3AA / TC3AAM
 
  DOT 3AA: W.P.3300 PSI (INCLUDING 10% OVERFILLING)
  3
  100
  232
  3.8
  EN 1964-1:1999 (PED)
 
  Approved PED 97/23/EC
  3
  100
  232
  3.4
  BS5045 P.1+ LATEST AMENDMENTS
  UK
 
  3
  100
  232
  3.4
  BS 5045-7:2000
  UK
  3
  100
  232
  3.4
  BS 5045-7:2000(PED)
  UK
  Approved PED 97/23/EC
  3
  100
  237
  3.9
  DOT EXEMPTION
 
 
  3
  100
  237
  3.9
  DOT / TC EXEMPTION
 
 
  3
  100
  300
  4.5
  BS5045 P.1+ LATEST AMENDMENTS
  E
 
  3
  100
  300
  4.5
  BS 5045-7:2000
  E
  3
  100
  300
  4.5
  BS 5045-7:2000(PED)
  UK
  Approved PED 97/23/EC
  3
  100
  300
  4.8
  EN 1964-1:1999
 
  3
  100
  300
  4.8
  EN 1964-1:1999 (PED)
 
  Approved PED 97/23/EC
  3
  100
  300
  5
  EUROPEAN REGULATIONS
 
  3
  100
  300
  5
  CEE/EEC/EWG 84/525 (EUROPE)
 
  3
  115
  200
  3.6
  EUROPEAN REGULATIONS
 
  3
  115
  200
  3.7
  CEE/EEC/EWG 84/525 FOR RINA
 
  3
  115
  200
  3.7
  CEE/EEC/EWG 84/525 (EUROPE)
 
  3
  115
  200
  3.8
  EN 1964-1:1999 (PED) FOR RINA
 
  Approved PED 97/23/EC
  3
  115
  200
  3.8
  EN 1964-1:1999 (PED)
 
  Approved PED 97/23/EC
  3
  115
  300
  4.2
  EUROPEAN REGULATIONS
 
  3
  140
  150
  3.6
  JPN HIGH PRESS.LAW-1998(APP.1)
 
 
  3.4
  100
  200
  3.8
  CEE/EEC/EWG 84/525 (EUROPE)
 
  3.4
  115
  200
  4
  CEE/EEC/EWG 84/525 (EUROPE)
 
  3.4
  115
  200
  4
  CEE/EEC/EWG 84/525 FOR RINA
 
  3.5
  100
  200
  3.9
  CEE/EEC/EWG 84/525 (EUROPE)
 
  3.5
  100
  200
  4.5
  EN 1964-1:1999
 
  3.5
  115
  200
  4.1
  CEE/EEC/EWG 84/525 FOR RINA
 
  3.5
  115
  200
  4.2
  EN 1964-1:1999 (PED) FOR RINA
 
  Approved PED 97/23/EC
  3.5
  115
  200
  4.2
  EN 1964-1:1999 (PED)
 
  Approved PED 97/23/EC
  3.5
  115
  300
  4.7
  EUROPEAN REGULATIONS
 
  3.5
  140
  150
  3.9
  JPN HIGH PRESS.LAW-1998(APP.1)
 
 
  4
  100
  200
  4.4
  CEE/EEC/EWG 84/525 (EUROPE)
 
  4
  100
  200
  4.6
  EN 1964-1:1999 (PED)
 
  Approved PED 97/23/EC
  4
  100
  200
  4.6
  EN 1964-1:1999 (PED) FOR RINA
 
  Approved PED 97/23/EC
  4
  100
  200
  5
  EN 1964-1:1999
 
  4
  100
  232
  4.6
  BS 5045-7:2000
  UK
  4
  100
  232
  4.6
  BS 5045-7:2000(PED)
  UK
  Approved PED 97/23/EC
  4
  100
  232
  4.6
  BS5045 P.1+ LATEST AMENDMENTS
  UK
 
  4
  100
  232
  4.9
  EN 1964-1:1999 (PED)
 
  Approved PED 97/23/EC
  4
  100
  300
  5.7
  BS 5045-7:2000
  E
  4
  100
  300
  5.7
  BS5045 P.1+ LATEST AMENDMENTS
  E
 
  4
  100
  300
  5.7
  BS 5045-7:2000(PED)
  UK
  Approved PED 97/23/EC
  4
  100
  300
  6.1
  EN 1964-1:1999 (PED)
 
  Approved PED 97/23/EC
  4
  100
  300
  6.1
  EN 1964-1:1999
 
  4
  115
  200
  4.6
  EN 1964-1:1999 (PED) FOR RINA
 
  Approved PED 97/23/EC
  4
  115
  200
  4.6
  CEE/EEC/EWG 84/525 FOR RINA
 
  4
  115
  200
  4.6
  EN 1964-1:1999 (PED)
 
  Approved PED 97/23/EC
  4
  115
  300
  5.3
  EUROPEAN REGULATIONS
 
  4
  140
  150
  4.3
  JPN HIGH PRESS.LAW-1998(APP.1)
 
 
  4
  140
  184
  5.3
  DOT 3AA / TC3AAM
 
  DOT 3AA: W.P.2640 PSI (INCLUDING 10% OVERFILLING)
  4
  140
  200
  4.9
  EN 1964-1:1999 (PED)
 
  Approved PED 97/23/EC
  4
  140
  200
  4.9
  EN 1964-1:1999 (PED) FOR RINA
 
  Approved PED 97/23/EC
  4
  140
  200
  4.9
  EN 1964-1:1999 FOR RUSSIA
 
 
  4
  140
  200
  4.9
  EN 1964-1:1999
 
  4
  140
  207
  6.5
  DOT 3AA
 
  DOT 3AA: W.P.3300 PSI (INCLUDING 10% OVERFILLING)
  4
  140
  232
  5.7
  EN 1964-1:1999 FOR RUSSIA
 
 
  4
  140
  232
  5.7
  EN 1964-1:1999
 
  4
  140
  232
  5.7
  EN 1964-1:1999 (PED)
 
  Approved PED 97/23/EC
  4
  140
  300
  7.2
  EN 1964-1:1999
 
  4
  140
  300
  7.2
  EN 1964-1:1999 (PED)
 
  Approved PED 97/23/EC
  4.5
  100
  200
  5.5
  EN 1964-1:1999
 
  4.5
  115
  200
  5.1
  CEE/EEC/EWG 84/525 FOR RINA
 
  4.5
  115
  200
  5.1
  CEE/EEC/EWG 84/525 (EUROPE)
 
  4.5
  140
  150
  4.6
  JPN HIGH PRESS.LAW-1998(APP.1)
 
 
  4.67
  100
  200
  5.7
  EN 1964-1:1999
 
  5
  100
  200
  5.7
  EN 1964-1:1999 (PED)
 
  Approved PED 97/23/EC
  5
  100
  200
  5.7
  EN 1964-1:1999 (PED) FOR RINA
 
  Approved PED 97/23/EC
  5
  100
  200
  6
  EN 1964-1:1999
 
  5
  100
  232
  6
  EN 1964-1:1999 (PED)
 
  Approved PED 97/23/EC
  5
  100
  232
  5.5
  BS 5045-7:2000(PED)
  UK
  Approved PED 97/23/EC
  5
  100
  232
  5.5
  BS 5045-7:2000
  UK
  5
  100
  232
  5.5
  BS5045 P.1+ LATEST AMENDMENTS
  UK
 
  5
  115
  200
  5.5
  CEE/EEC/EWG 84/525 FOR RINA
 
  5
  115
  200
  5.5
  EN 1964-1:1999 (PED) FOR RINA
 
  Approved PED 97/23/EC
  5
  115
  200
  5.5
  CEE/EEC/EWG 84/525 (EUROPE)
 
  5
  115
  200
  5.5
  EN 1964-1:1999 (PED)
 
  Approved PED 97/23/EC
  5
  140
  150
  5
  JPN HIGH PRESS.LAW-1998(APP.1)
 
 
  5
  140
  200
  5.5
  CEE/EEC/EWG 84/525 FOR RINA
 
  5
  140
  200
  5.7
  EN 1964-1:1999 (PED) FOR RINA
 
  Approved PED 97/23/EC
  5
  140
  200
  5.7
  EN 1964-1:1999 FOR RUSSIA
 
 
  5
  140
  200
  5.7
  EN 1964-1:1999
 
  5
  140
  200
  5.7
  EN 1964-1:1999 (PED)
 
  Approved PED 97/23/EC
  5
  140
  207
  5.5
  BS5045 P.1+ LATEST AMENDMENTS
  E
 
  5
  140
  207
  5.5
  BS5045 P.1 FOR INDIA
  E
 
  5
  140
  232
  5.8
  BS 5045-7:2000(PED)
  UK
  Approved PED 97/23/EC
  5
  140
  232
  5.8
  BS5045 P.1+ LATEST AMENDMENTS
  UK
 
  5
  140
  232
  5.8
  BS 5045-7:2000
  UK
  5
  140
  232
  6.6
  EN 1964-1:1999 FOR RUSSIA
 
 
  5
  140
  232
  6.6
  EN 1964-1:1999
 
  5
  140
  232
  6.6
  EN 1964-1:1999 (PED)
 
  Approved PED 97/23/EC
  5
  140
  237
  6.7
  DOT / TC EXEMPTION
 
 
  5
  140
  237
  6.7
  DOT EXEMPTION
 
 
  5
  140
  300
  7.5
  BS 5045-7:2000(PED)
  UK
  Approved PED 97/23/EC
  5
  140
  300
  7.5
  BS 5045-7:2000
  E
  5
  140
  300
  7.6
  CEE/EEC/EWG 84/525 (EUROPE)
 
  5
  140
  300
  8.4
  EN 1964-1:1999 (PED)
 
  Approved PED 97/23/EC
  5
  140
  300
  8.4
  EN 1964-1:1999
 
  5.5
  115
  200
  6
  CEE/EEC/EWG 84/525 FOR RINA
 
  5.5
  115
  200
  6
  CEE/EEC/EWG 84/525 (EUROPE)
 

Notes :

-Diameter, capacity and weight are nominal
-Actual values can differ from nominal
-Availability for all cylinders to be confirmed by Faber
-All cylinders are manufactured from steel plate with convex bottom ( unless specified "concave bottom")
-"European Regulations" : Regulations of Austria, Czech Rep., Finland, France, Germany, Poland, Slovakia, Spain, Sweden, Hungary, Rumania, Switzerland (depending on the cylinders - See note for EU Countries)

- New Cylinders for EU Countries must be approved according to Pressure Equipment Directive PED 97/23/CE ( www.divefaber.com/eu-ped.htm )
-For DOT3AA (USA) cylinders the 10% overfill is allowed if a plus (+) symbol is marked on the dome of the cylinder.
-Do not exceed the allowed filling pressure (W.P.).
-More technical information including, length, buoyancy in sea water and fresh water, "real weight", drawing prints are available at www.divefaber.com selecting Dive Faber Dbase & Drawings from menu
-See Legal Disclaimer at www.divefaber.com/legal.htm


© 1998 - 2010 Faber Industrie S. p. A.